NRAO Home > CASA > CASA Task Reference Manual

0.1.88 polcal

Requires:

Synopsis
Determine instrumental polarization calibrations

Description

The complex instrumental polarization factors (D-terms) for each antenna/spwid are determined from the data for the specified calibrator sources. Previous calibrations can be applied on the fly.

Arguments





Inputs

vis

Name of input visibility file

allowed:

string

Default:

caltable

Name of output gain calibration table

allowed:

string

Default:

field

Select field using field id(s) or field name(s)

allowed:

string

Default:

spw

Select spectral window/channels

allowed:

string

Default:

intent

Select observing intent

allowed:

string

Default:

selectdata

Other data selection parameters

allowed:

bool

Default:

True

timerange

Select data based on time range

allowed:

string

Default:

uvrange

Select data within uvrange (default units meters)

allowed:

any

Default:

variant

antenna

Select data based on antenna/baseline

allowed:

string

Default:

scan

Scan number range

allowed:

string

Default:

observation

Select by observation ID(s)

allowed:

any

Default:

variant

msselect

Optional complex data selection (ignore for now)

allowed:

string

Default:

solint

Solution interval

allowed:

any

Default:

variant inf

combine

Data axes which to combine for solve (obs, scan, spw, and/or field)

allowed:

string

Default:

obs,scan

preavg

Pre-averaging interval (sec)

allowed:

double

Default:

300.0

refant

Reference antenna name(s)

allowed:

string

Default:

minblperant

Minimum baselines _per antenna_ required for solve

allowed:

int

Default:

4

minsnr

Reject solutions below this SNR

allowed:

double

Default:

3.0

poltype

Type of instrumental polarization solution (see help)

allowed:

string

Default:

D+QU

smodel

Point source Stokes parameters for source model.

allowed:

doubleArray

Default:

append

Append solutions to the (existing) table

allowed:

bool

Default:

False

docallib

Use callib or traditional cal apply parameters

allowed:

bool

Default:

False

callib

Cal Library filename

allowed:

string

Default:

gaintable

Gain calibration table(s) to apply

allowed:

stringArray

Default:

gainfield

Select a subset of calibrators from gaintable(s)

allowed:

stringArray

Default:

interp

Interpolation mode (in time) to use for each gaintable

allowed:

stringArray

Default:

spwmap

Spectral windows combinations to form for gaintables(s)

allowed:

intArray

Default:

Example

 
 
      The instrumental polarization factors (D-terms), the calibrator polarization,  
      and the R-L polarization angle can be determined using polcal.  The solutions  
      can be obtained for each antenna/spwid and even individual channels, if desired.  
      Previous calibrations of the total intensity data should be applied on the fly  
      when running polcal, since polcal uses the ’data’ column, not the ’corrected’  
      column.  
 
      After calibrating the gain, bandpass, and (if relevant, for channelized data)  
      cross-hand delay, the simplest way to calibrate the polarization data is:  
 
        a) Run polcal with poltype = ’D+QU’ on the main ’calibrator’ source.  The D terms  
           and polarization (QU) of the calibrator will be determined.  Relatively good  
           parallactic angle coverage is needed.  
 
        b) If there is little parallactic angle coverage, place the known polarization of  
           the main calibrator (or 0) using setjy with the appropriate fluxdensity.  Then  
           run polcal with poltype = ’D’.  Run plotcal with xaxis = ’real’; yaxis =’imag’  
           to view solutions.  It is best to use an unpolarized calibrator in this  
           instance; large systematic offsets from zero indicate significant source  
           polarization that will bias the polarization calibration.  A mechanism  
           to constrain this bias will be made available in the near future.  
 
        c) To determine R-L polarization angle, use setjy to put the fluxdensity of the  
           polarization calibrator [I,Q,U,0.0] in the model column.  For resolved sources  
           put in values associated with an appropriate u-v range.  Polarized models are  
           not yet available for the major polarization standard sources, so very  
           resolved polarized sources should not be used.  
 
        d) Run polcal with poltype = ’X’ and include polarization standard.  Make sure to  
           include all previous calibrations, especially the D results.  Run plotxy with  
           correlation = ’RL LR’ and make sure polarization angles are as expected.  
 
        e) Run applycal with all calibration table, include the D and X tables.  Make sure  
           that parang = T  
 
         NOTE: For very high dynamic range, use poltype=’Df’ or ’Df+QU’ to determine  
               D terms for each channel.  Similarly, poltype=’Xf’ can  
               be used to determine a channel-dependent R-L phase  
               "bandpass".  
         NOTE: Rather than use setjy in b and c above, the new smodel  
               parameter may be used in polcal to specify a simple  
               point source Stokes model.  
 
      Keyword arguments:  
      vis -- Name of input visibility file  
              default: none; example: vis=’ngc5921.ms’  
      caltable -- Name of output gain calibration table  
              default: none; example: caltable=’ngc5921.dcal’  
 
      --- Data Selection (see help par.selectdata for more detailed information)  
 
      field -- Select field using field id(s) or field name(s).  
                 [run listobs to obtain the list id’s or names]  
              default: ’’=all fields.  
                  Most likely, the main calibrator source should be picked.  
              If field string is a non-negative integer, it is assumed a field index  
                otherwise, it is assumed a field name  
              field=’0~2’; field ids 0,1,2  
              field=’0,4,5~7’; field ids 0,4,5,6,7  
              field=’3C286,3C295’; field named 3C286 adn 3C295  
              field = ’3,4C*’; field id 3, all names starting with 4C  
      spw -- Select spectral window/channels  
               type ’help par.selection’ for more examples.  
             spw=’0~2,4’; spectral windows 0,1,2,4 (all channels)  
             spw=’<2’;  spectral windows less than 2 (i.e. 0,1)  
             spw=’0:5~61’; spw 0, channels 5 to 61, INCLUSIVE  
             spw=’*:5~61’; all spw with channels 5 to 62  
             spw=’0,10,3:3~45’; spw 0,10 all channels, spw 3, channels 3 to 45.  
             spw=’0~2:2~6’; spw 0,1,2 with channels 2 through 6 in each.  
             spw=’0:0~10;15~60’; spectral window 0 with channels 0-10,15-60  
                       NOTE ’;’ to separate channel selections  
             spw=’0:0~10^2,1:20~30^5’; spw 0, channels 0,2,4,6,8,10,  
                   spw 1, channels 20,25,30  
      intent -- Select observing intent  
                default: ’’  (no selection by intent)  
                intent=’*BANDPASS*’  (selects data labelled with  
                                      BANDPASS intent)  
      selectdata -- Other data selection parameters  
              default: True  
      timerange  -- Select data based on time range:  
              default = ’’ (all); examples,  
              timerange = ’YYYY/MM/DD/hh:mm:ss~YYYY/MM/DD/hh:mm:ss’  
              Note: if YYYY/MM/DD is missing dat defaults to first day in data set  
              timerange=’09:14:0~09:54:0’ picks 40 min on first day  
              timerange= ’25:00:00~27:30:00’ picks 1 hr to 3 hr 30min on next day  
              timerange=’09:44:00’ data within one integration of time  
              timerange=’>10:24:00’ data after this time  
      uvrange -- Select data within uvrange (default units meters)  
              default: ’’ (all); example:  
              uvrange=’0~1000klambda’; uvrange from 0-1000 kilo-lambda  
              uvrange=’>4klambda’;uvranges greater than 4 kilo-lambda  
      antenna -- Select data based on antenna/baseline  
              default: ’’ (all)  
              If antenna string is a non-negative integer, it is assumed an antenna index  
                otherwise, it is assumed as an antenna name  
              antenna=’5&6’; baseline between antenna index 5 and index 6.  
              antenna=’VA05&VA06’; baseline between VLA antenna 5 and 6.  
              antenna=’5&6;7&8’; baseline 5-6 and 7-8  
              antenna=’5’; all baselines with antenna index 5  
              antenna=’05’; all baselines with antenna name 05, i.e. VLA ant 5  
              antenna=’5,6,10’; all baselines with antennas 5, 6 and 10  
      scan -- Scan number range  
      observation -- Observation ID(s).  
                     default: ’’ = all  
                     example: ’0~2,4’  
      msselect -- Optional complex data selection (ignore for now)  
 
      --- Solution parameters  
      poltype -- Type of instrumental polarization solution  
              ’D+QU’ (or ’Df+QU’)  solve also for apparent source polarization (channelized D)  
                 Need relatively good parallactic angle coverage for this  
              ’D’ (or ’Df’) solve only for instrumental polarization (channelized).  The  
                 I, Q, U flux density of the source can be placed in the model column using  
                 setjy.  Use for poor parallactic angle coverage.  
              ’X’ (or ’Xf’) = solve only for position angle correction (channelized).  
                 The source must have its I, Q, U flux density in the model column  
                 or specified in smodel.  If the source is resolved, use a limited  
                 uvrange that is appropriate.  
              ’D+X’ (or ’Df+X’) = solve also for position angle offset (channelized D) as  
                 well as the D-term.  Not normally done.  
              default: ’D+QU’  
              The solution used the traditional linear approximation.  Non-linearized options  
                  will be avaible soon.  
      smodel -- Point source Stokes parameters for source model (experimental)  
              default: [] (use MODEL_DATA column)  
              examples: [1,0,0,0] (I=1, unpolarized)  
                        [5.2,0.2,0.3,0.0] (I=5.2, Q=0.2, U=0.3, V=0.0)  
      solint --  Solution interval (units optional)  
              default: ’inf’ (~infinite, up to boundaries controlled by combine);  
              Options: ’inf’ (~infinite), ’int’ (per integration), any float  
                       or integer value with or without units  
              examples: solint=’1min’; solint=’60s’, solint=60 --> 1 minute  
                        solint=’0s’; solint=0; solint=’int’ --> per integration  
                        solint-’-1s’; solint=’inf’ --> ~infinite, up to boundaries  
                        enforced by combine  
      combine -- Data axes to combine for solving  
              default: ’obs,scan’ --> solutions will break at field and spw  
                      boundaries but may extend over multiple obs and scans  
                      (per field and spw) up to solint.  
              Options: ’’,’obs’,’scan’,’spw’,field’, or any comma-separated  
                       combination in a single string  
              example: combine=’scan,spw’ --> extend solutions over scan boundaries  
                       (up to the solint), and combine spws for solving  
      preavg -- Pre-averaging interval (sec)  
              default=300  
              Interval to apply parallactic angle.  
      refant -- Reference antenna name  
              default: ’’ => refant = ’0’  
              example: refant=’13’ (antenna with index 13)  
                       refant=’VA04’ (VLA antenna #4)  
                       refant=’EA02,EA23,EA13’ (EVLA antenna EA02, use  
                                EA23 and EA13 as alternates if/when EA02  
                                drops out)  
              Use ’go listobs’ for antenna listing.  
              USE SAME REFERENCE ANTENNA AS USED FOR I CALIBRATION.  
      minblperant -- Minimum number of baselines required per antenna for each solve  
                   Antennas with fewer baaselines are excluded from solutions. Amplitude  
                   solutions with fewer than 4 baselines, and phase solutions with fewer  
                   than 3 baselines are only trivially constrained, and are no better  
                   than baseline-based solutions.  
                   default: 4  
                   example: minblperant=10  => Antennas participating on 10 or more  
                            baselines are included in the solve  
      minsnr -- Reject solutions below this SNR  
              default: 3.0  
      append -- Append solutions to the (existing) table.  Appended solutions  
                  must be derived from the same MS as the existing  
                  caltable, and solution spws must have the same  
                   meta-info (according to spw selection and solint)  
                   or be non-overlapping.  
              default: False; overwrite existing table or make new table  
 
      --- Other calibrations to apply on the fly before determining polcal solution  
 
      docallib -- Control means of specifying the caltables:  
               default: False ==> Use gaintable,gainfield,interp,spwmap,calwt  
                        If True, specify a file containing cal library in callib  
      callib -- If docallib=True, specify a file containing cal  
                  library directives  
 
      gaintable -- Gain calibration table(s) to apply  
               default: ’’ (none);  BUT I CALIBRATION TABLES SHOULD GENERALLY BE INCLUDED  
               examples: gaintable=’ngc5921.gcal’  
                         gaintable=[’ngc5921.ampcal’,’ngc5921.phcal’]  
      gainfield -- Select a subset of calibrators from gaintable(s)  
               default:’’ ==> all sources in table;  
               ’nearest’ ==> nearest (on sky) available field in table  
               otherwise, same syntax as field  
               example: gainfield=’0~3’  
                        gainfield=[’0~3’,’4~6’] means use field 0 through 3  
                          from first gain file, field 4 through 6 for second.  
      interp -- Interpolation type (in time[,freq]) to use for each gaintable.  
                When frequency interpolation is relevant (B, Df, Xf),  
                separate time-dependent and freq-dependent interp  
                types with a comma (freq _after_ the comma).  
                Specifications for frequency are ignored when the  
                calibration table has no channel-dependence.  
                Time-dependent interp options ending in ’PD’ enable a  
                "phase delay" correction per spw for non-channel-dependent  
                calibration types.  
                For multi-obsId datasets, ’perobs’ can be appended to  
                the time-dependent interpolation specification to  
                enforce obsId boundaries when interpolating in time.  
                default: ’’ --> ’linear,linear’ for all gaintable(s)  
                example: interp=’nearest’   (in time, freq-dep will be  
                                             linear, if relevant)  
                         interp=’linear,cubic’  (linear in time, cubic  
                                                 in freq)  
                         interp=’linearperobs,spline’ (linear in time  
                                                       per obsId,  
                                                       spline in freq)  
                         interp=’,spline’  (spline in freq; linear in  
                                            time by default)  
                         interp=[’nearest,spline’,’linear’]  (for multiple gaintables)  
                Options: Time: ’nearest’, ’linear’  
                         Freq: ’nearest’, ’linear’, ’cubic’, ’spline’  
      spwmap -- Spectral windows combinations to form for gaintable(s)  
                default: [] (apply solutions from each spw to that spw only)  
                Example:  spwmap=[0,0,1,1] means apply the caltable solutions  
                          from spw = 0 to the spw 0,1 and spw 1 to spw 2,3.  
                          spwmap=[[0,0,1,1],[0,1,0,1]]  
      async --  Run asynchronously  
               default = False; do not run asychronously  


More information about CASA may be found at the CASA web page

Copyright © 2016 Associated Universities Inc., Washington, D.C.

This code is available under the terms of the GNU General Public Lincense


Home | Contact Us | Directories | Site Map | Help | Privacy Policy | Search