NRAO Home > CASA > CASA Task Reference Manual |
|
0.1.133 testconcat
Requires:
Synopsis
Concatenate the subtables of several visibility data sets, not the MAIN bulk
data.
Arguments
Inputs |
| ||
vis |
| Name(s) of input visibility files to be test-concatenated
| |
| allowed: | stringArray |
|
| Default: |
| |
testconcatvis |
| Name of output MS containing the merged subtables
| |
| allowed: | string |
|
| Default: |
| |
freqtol |
| Frequency shift tolerance for considering data as the
same spwid
| |
| allowed: | any |
|
| Default: | variant
|
|
dirtol |
| Direction shift tolerance for considering data as the same
field
| |
| allowed: | any |
|
| Default: | variant
|
|
copypointing |
| Copy all rows of the POINTING table.
| |
| allowed: | bool |
|
| Default: | True |
|
The list of data sets given in the vis argument are concatenated into an output
data set in testconcatvis without the bulk data of the MAIN table.
This is useful for obtaining the information in the merged subtables without
actually performing a time-consuming concatenation of the MAIN tables on disk.
Keyword arguments:
vis -- Name of input visibility files for which the subtables are to be combined
default: none; example: vis = ’mydata.ms’,
vis=[’src2.ms’,’ngc5921.ms’,’ngc315.ms’]
testconcatvis -- Name of MS that will contain the concatenated subtables
default: none; example: testconcatvis=’test.ms’
freqtol -- Frequency shift tolerance for considering data to be in the same
spwid. The number of channels must also be the same.
default: ’’ do not combine unless frequencies are equal
example: freqtol=’10MHz’ will not combine spwid unless they are
within 10 MHz.
Note: This option is useful to conbine spectral windows with very slight
frequency differences caused by Doppler tracking, for example.
dirtol -- Direction shift tolerance for considering data as the same field
default: ’’ means always combine.
example: dirtol=’1.arcsec’ will not combine data for a field unless
their phase center differ by less than 1 arcsec. If the field names
are different in the input data sets, the name in the output data
set will be the first relevant data set in the list.
copypointing -- Make a proper copy of the POINTING subtable (can be time consuming).
If False, the result is an empty POINTING table.
default: True
More information about CASA may be found at the
CASA web page
Copyright © 2016 Associated Universities Inc., Washington, D.C.
This code is available under the terms of the GNU General Public Lincense
Home |
Contact Us |
Directories |
Site Map |
Help |
Privacy Policy |